Sign In | Join Free | My enlightcorp.com
China Xi'an Yunyi Instrument Co., Ltd logo
Xi'an Yunyi Instrument Co., Ltd
Xi'an Yunyiyibiao Instrument Co., Ltd. is a national high-tech enterprise, specializing in the R&D, production and sales of pressure transmitter,level meter, flow , temperature instrument and
Verified Supplier

5 Years

Home > Differential Pressure Transmitter >

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor

Xi'an Yunyi Instrument Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor

Brand Name : YunYi

Model Number : UC800

Place of Origin : China

MOQ : 1 piece

Price : USD161.00-USD279.00 PER PIECE

Payment Terms : T/T, Western Union

Supply Ability : 1000 Piece/Pieces per Month

Delivery Time : 10DAYS

Packaging Details : Standard export package

product : 3051 Vacuum Pressure Sensor

Display : 4 digital display,5 digit LCD display, pointer type.

Temperature : ambient temperature -40-85℃

Medium temperature : -40~104℃

Relative humidity : 5~98%RH

Run-up time : less than 5 sec.

Capability change : Less than 0.16cm3

Contact Now

Transmitter 420 Ma 4-20 400 Bar 3051 Vacuum Pressure Sensor

Description 3051 Intelligent Capacitive Differential Pressure transducer

3051 Project Special Pressure Transmitter is the result of a combination of self-developed anti-jamming, high stability digital circuits and
the introduction of foreign Single crystal resonant silicon sensor technology. Its performance much better than our domestic metal capacitive sensortechnology transmitter, and main show in the field zero stability and long-term operation stability, and rapid response.

Detailed Images 3051 Intelligent Capacitive Differential Pressure transducer

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor

Specification 3051 Intelligent Capacitive Differential Pressure transducer

Range code Range Measuring range
Min. Max.
4 0.374KPa 37.4KPa -37.4~37.4KPa
5 1.868KPa 186.8KPa -186.8~186.8KPa
6 6.9KPa 690KPa -690~690KPa
7 20.68KPa 2068KPa -2068~2068KPa

Technical Data Capacitive

Output Analog output: two –wire 4-20mADC
Digital output: two –wire 4-20mADC and superimposing variable digital signal accord with HART
Power supply supply voltage 24VDC
Limit load Max load resistor Rmax in loop decided by the supply voltage, see the below drawing. HART PROTOCOL require the load resistor not less than 250Ω,not more than 600Ω
Communication distance Max. 1.5Km, multi-address communication can connect 15 smart transmitters Max.
Display 4 digital display,5 digit LCD display, pointer type.
Explosion-proof ExiaIICT5;explosion suppression type
Zero offset Can positive transfer or negative transfer, but can not overstep the utmost value
Temperature ambient temperature -40-85℃(When choose LCD : -20-70℃)
Medium temperature -40~104℃
Static pressure and single side overpressure 3.45KPa(absolute pressure)~31.2MPa(gauge pressure)
Relative humidity 5~98%RH
Run-up time less than 5 sec.
Capability change Less than 0.16cm3
Damp adjust 0.20~25 second
Malfunction alarming If occur malfunction, automatism diagnose function will output 3.9 or 21.0mA
Configuration protection To avoid the datas are modified random, can utilize software or protect switch lock the record data

Reference condition

zero is the lower limit and not offset, temperature 25℃, Atmospheric pressure, 24VDC power,

silicon oil , diaphragm 316L, data adjust range the same as the up and lower limit of the range.

Accuracy ±0.075~±0.2%
Stability ≤0.2%URL/year
Tem. influence ±(0.05%URL+0.15%FS+200Pa)20℃
Static pressure influence zero error 0.1URL/6.9Mpa; Zero error 0.1URL/1.7MPa
Vibration influence withstand frequency 200Hz at any direction, arouse error ±0.05%URL
Power influence <0.005%/V
Load influence no load influence
Mounting position influence about 250Pa zero offset, can be eliminate via calibration, no range influence.
RF interference influence drift is ±0.1%span in the condition of 30-1000MHz frequency and the most field intensity 10V/m

Note:The model belongs to the project special pressure transmitter ,all data can be custom according to the customers requirements.

Features 3051 Intelligent Capacitive Differential Pressure transducer

Single crystal resonant silicon sensor technology
Super performance, use to measure pressure, differential pressure and temperature..
Accuracy: ±0.075%~±0.1%F.S/±0.2%F.S
Stability: ≤0.2%
Standard 4~20mA,RS-485 communication interface
Support upgrade of basic scene control technique

Little temperature effect

Little static effect

Applications 3051 Intelligent Capacitive Differential Pressure transducer

Single crystal resonant silicon sensor technology
Super performance, use to measure pressure, differential pressure and temperature..
Accuracy: ±0.075%~±0.1%F.S/±0.2%F.S
Stability: ≤0.2%
Standard 4~20mA,RS-485 communication interface
Support upgrade of basic scene control technique

Little temperature effect

Little static effect

Overload can reach 2 times

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor


Product Tags:

420Ma Differential Pressure Transmitter

      

3051 Vacuum Pressure Sensor

      

400 Bar Vacuum Pressure Sensor

      
Quality 420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor for sale

420Ma 4-20 400 Bar Differential Pressure Transmitter 3051 Vacuum Pressure Sensor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Yunyi Instrument Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)